Refitting the cable harness in the base
NoteAction
xx1300000732
Run the cables through the protection tube
in this order:
R1.MP
R1.SMB
If necessary, lubricate the cables with
grease to make them run more smoothly.
1
xx1300000736
Make sure that the cables are not
twisted. Each cable must be in line
with its position on the base plate.
Make sure that the R1.SMB cable
will run on the correct side of the
R1.MP1, see the figure.
2
Make sure that the markings on the cables
are facing the base cover, when connected.
3
Tightening torque for R1.SMB: 10 Nm.
xx1300000591
Connect connectors R1.MP and R1.SMB.4
Continues on next page
258 Product manual - IRB 6700
3HAC044266-001 Revision: N
© Copyright 2013 - 2018 ABB. All rights reserved.
4 Repair
4.4.2 Refitting the cable harness