xx1300001113
Pull out the carrier from its position.6
xx1300000666
Pull out the axis-6 motor cables by holding
the cables with one hand at the motor and
the other at the carrier.
7
Disconnecting the axis-3 and axis-4 motor cables
NoteAction
DANGER
Make sure that all supplies for electrical
power, hydraulic pressure, and air pressure
are turned off.
1
xx1200001135
Unscrew the attachment screws and
washers and remove the motor cover.
2
Continues on next page
306 Product manual - IRB 6700
3HAC044266-001 Revision: N
© Copyright 2013 - 2018 ABB. All rights reserved.
4 Repair
4.5.1 Replacing the upper arm