NoteAction
Tightening torque: 45 NmFit the Distance tool on the back of the
balancing device using the four screws.
DANGER
Use caution when tightening the screws.
The threads in the cover can be damaged
if more tightening torque than 45 Nm is
used, risking that the Distance tool is not
properly fitted.
5
Attachment screws: M10 quality 12.9 (4
pcs)
xx0800000480
A Distance tool: 3HAC030662-001
Turn the power on temporary.6
This is done to compress the balancing
device springs, making it possible to re-
move the front shaft of the balancing
device.
Jog axis-2 to the calibration position.
The balancing device is now unloaded.
7
Let the Distance tool stay fitted during the
continued procedure.
8
DANGER
Turn off all:
• electric power supply
• hydraulic pressure supply
• air pressure supply
to the robot, before entering the robot
working area.
9
Preparations before removing the balancing device
NoteAction
Jog axis-2 to the calibration position (if not
already in this position).
1
Continues on next page
Product manual - IRB 6700 465
3HAC044266-001 Revision: N
© Copyright 2013 - 2018 ABB. All rights reserved.
4 Repair
4.6.2 Replacing the balancing device