NoteAction
xx1200001070
Make sure the o-ring is present.3
xx1200001066
Disconnect the motor cables.4
xx1200001067
Remove the cable gland cover.
Make sure the gasket is not damaged.
Tip
Make a note in which direction the cable
gland hole is facing, if the motor will be re-
moved too. The motor shall be refitted in
the same position.
5
Use caution and pull out the motor cables.6
Removing the axis-2 motor
NoteAction
Before removing the motor, make sure that
the axis-2 gearbox is completely drained.
1
Continues on next page
Product manual - IRB 6700 521
3HAC044266-001 Revision: N
© Copyright 2013 - 2018 ABB. All rights reserved.
4 Repair
4.7.2 Replacing the axis-2 motor
Continued