Removing the axis-6 motor
Use these procedures to remove the motor.
Preparations before removing the axis-6 motor
NoteAction
Decide which calibration routine to use,
and take actions accordingly prior to begin-
ning the repair procedure.
1
xx1200001081
Jog the robot to a position where axis 5
can be positioned with the motor pointing
straight up at an acceptable working posi-
tion.
With axis 5 in this position it is possible to
replace the motor without draining the oil
from the axis-6 gearbox.
2
DANGER
Turn off all:
electric power supply
hydraulic pressure supply
air pressure supply
to the robot, before entering the robot
working area.
3
xx1300002247
Remove the wrist cover.4