EasyManua.ls Logo

ABB IRB 6700 Series - Page 574

ABB IRB 6700 Series
846 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Disconnecting the axis-6 motor cables
NoteAction
DANGER
Make sure that all supplies for electrical
power, hydraulic pressure, and air pressure
are turned off.
1
xx1200001080
Unscrew the attachment screws and re-
move the motor cover.
2
xx1300000488
Disconnect the motor cables.3
xx1300000484
Unscrew the attachment screws that hold
the cable bracket.
4
Continues on next page
574 Product manual - IRB 6700
3HAC044266-001 Revision: N