NoteAction
Wipe clean o-ring and o-ring groove.5
Refit the o-ring.
Tip
Lubricate the o-ring with some grease for
a better fitting in the groove.
6
CAUTION
When fitting the motor cover, make sure
that none of the cables inside will be dam-
aged.
7
Attachment screws: M5x12 8.8 (7 pcs)
xx1200001135
Refit the motor cover with its attachment
screws.
Note
Do not reuse the self-threading attachment
screws. Replace with standard attachment
screws or the threads will be damaged.
Note
Make sure the o-ring is undamaged and
properly fitted.
8
Make sure that the covers are tightly
sealed.
9
Refitting the cabling
Use this procedure to refit the cabling.
NoteAction
Use caution and push the cable harness
into the lower arm.
1
Continues on next page