Removing the spherical roller bearing
Use these procedures to remove the spherical roller bearing in the link ear.
Preparations before removing the spherical roller bearing
NoteAction
xx2200001458
Jog axis-2 to the calibration position.1
Lock screw, M16x120Fit a lock screw through the hole for the
lock screw in the frame and into the lower
arm to secure the weight of the lower and
upper arms.
CAUTION
Do not tighten the lock screw, since too
hard tightening could damage the gear.
2
xx2200001332
DANGER
Turn off all:
electric power supply
hydraulic pressure supply
air pressure supply
to the robot, before entering the safe-
guarded space.
3
Remove any installed equipment on or
close to the balancing device.
4
Continues on next page
206 Product manual - IRB 6710
3HAC085695-001 Revision: A
© Copyright 2023 ABB. All rights reserved.
5 Repair
5.3.2 Replacing spherical roller bearing, balancing device link ear