Restoring the balancing device and removing the Hydraulic press equipment, balancing device
NoteAction
User instructions are enclosed with the
tool.
Restore the balancing device and remove
the press equipment according to instruc-
tions for the press equipment.
xx0900000813
Go to the user instructions enclosed with
the press tool.
DANGER
Handling the tool incorrectly will cause
serious injury.
Read and follow enclosed user instructions
for the tool.
Hex socket head cap screw: M10x25 8.8-
A3F.
Apply flange sealant and refit the cover
plate on the back of the balancing device.
1
Tightening torque: 50 Nm.
Flange sealant for conical fittings: Loctite
5400 (or equivalent Loctite 577).
xx2200001330
Concluding procedure
NoteAction
DANGER
Make sure all safety requirements are met
when performing the first test run. See Test
run after installation, maintenance, or repair
on page 94.
1
230 Product manual - IRB 6710
3HAC085695-001 Revision: A
© Copyright 2023 ABB. All rights reserved.
5 Repair
5.3.3 Replacing the rear bearings on the balancing device
Continued