NoteAction
Torx pan head screw: M6x16 A4-80Secure the cable bracket with its attach-
ment screws.
5
Tightening torque: standard torque 10 Nm
(Tightening torque on page 625)..
xx1300000484
Connecting the axis-6 motor cables
NoteAction
Connect the motor cables.1
Connect in accordance with the markings
on the connectors.
Tightening torque: 1 NmPosition the power connector to the bracket
with a screw.
Note
The purpose of the screw is to secure the
mating of the connectors and the position-
ing of the connector in the connection box.
It is normal that the connector can be
moved back and forth after the screw has
been tightened according to the torque
specification and, in some connection
boxes, that the screw is not even fully inser-
ted when it bottoms.
2
xx2200001919
Continues on next page
Product manual - IRB 6710 255
3HAC085695-001 Revision: A
© Copyright 2023 ABB. All rights reserved.
5 Repair
5.4.1 Replacing the arm house cover including the axis-4 cassette sealing
Continued