NoteAction
Torx pan head tapping screw:
Steel-Fe/Zn 8c M6x16
Fit brake release unit into the electronic box and se-
cure with the screws.
2
Tightening torque: 10 Nm.
xx2200001728
Refitting and connecting the SMB unit
NoteAction
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
1
ELECTROSTATIC DISCHARGE (ESD)
The unit is sensitive to ESD. Before handling the
unit read the safety information in section The
unit is sensitive to ESD on page 48.
2
Cover, electronics:Check the electronic box gasket.3
3HAC081189-003 (Graphite White)Replace if damaged.
3HAC081189-004 (ABB Orange)
xx2200001724
Fit the SMB unit into the electronic box.4
Continues on next page
Product manual - IRB 6710 339
3HAC085695-001 Revision: A
© Copyright 2023 ABB. All rights reserved.
5 Repair
5.6.3 Replacing the brake release unit
Continued

Table of Contents