Inspecting, signal lamp
Use this procedure to inspect the function of the signal lamp.
NoteAction
Inspect that signal lamp is lit when motors are put in
operation ("MOTORS ON").
1
DANGER
Turn off all:
electric power supply
hydraulic pressure supply
air pressure supply
to the robot, before entering the robot working area.
2
Article number is specified in Re-
quired tools and equipment on
page 122.
If the lamp is not lit, trace the fault by:
inspecting whether the signal lamp is broken.
If so, replace it.
inspecting cable connections.
measuring the voltage in the connectors of
motor axis 6 (=24V).
inspecting the cabling. Replace the cabling if
a fault is detected.
3
Product manual - IRB 760 123
3HAC039838-001 Revision: M