3.3.7 Inspecting the axis-1 mechanical stop pin
WARNING
Mechanical stop pin can not be fitted onto robot if option 810-1 Electronic Position
Switch is used.
WARNING
Mechanical stop pin can not be fitted onto robot if option 561-1 Extended work
range axis 1 is used.
Location of mechanical stop pin
The axis-1 mechanical stop is located as shown in the figure.
xx0600002695
Mechanical stop pinA
Fixed stopB
Required equipment
Visual inspection, no tools are required.
Inspecting, mechanical stop pin
Use this procedure to inspect the axis-1 mechanical stop pin.
NoteAction
DANGER
Turn off all:
electric power supply
hydraulic pressure supply
air pressure supply
to the robot, before entering the robot working
area.
1
Continues on next page
116 Product manual - IRB 760
3HAC039838-001 Revision: M
© Copyright 2011-2018 ABB. All rights reserved.
3 Maintenance
3.3.7 Inspecting the axis-1 mechanical stop pin

Table of Contents

Related product manuals