3.4.4 Changing oil, gearbox axis 6
Location of oil plugs
Gearbox axis 6 is located in the center of the tilt house unit.
xx1000001236
Oil plug, fillingA
Oil plug, drainingB
Gearbox, axis 6C
Required equipment
NoteAmountArt. no.Equipment, etc.
Kyodo Yushi TMO 150850 ml3HAC032140-001Lubrication oil
Do not mix with other oil types!
3HAC021745-001Oil exchange equipment
Vessel capacity: 900 ml.Oil collecting vessel
Content is defined in section
Standard tools on page 389.
-Standard toolkit
Draining, oil
Use this procedure to drain oil from gearbox axis 6.
When using oil change equipment, follow the instructions enclosed with kit.
NoteAction
Put tilt house in a suitable position.1
Continues on next page
Product manual - IRB 760 133
3HAC039838-001 Revision: M
© Copyright 2011-2018 ABB. All rights reserved.