EasyManua.ls Logo

ABB IRB 760 Series - Page 159

ABB IRB 760 Series
402 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
NoteAction
xx1000001331
Gently pull the cable harness out from the base
through the cable guide, axis 1 and frame.
16
See section Replacing the cable har-
ness, upper end (incl. axis 6) on
page 163.
Continue removing the cable harness in the
upper arm.
17
Refitting, cable harness - lower end (axes 1-3)
Use this procedure to refit the cable harness, lower end (axes 1-3).
NoteAction
xx1000001331
Push the cable harness and connectors down
through the cable guide axis 1 in the center of
the frame.
CAUTION
Make sure the cables are not twisted with each
other or with customer harness (if any)!
1
Continues on next page
Product manual - IRB 760 159
3HAC039838-001 Revision: M
© Copyright 2011-2018 ABB. All rights reserved.
4 Repair
4.3.1 Replacing cable harness, lower end (axes 1-3)
Continued

Table of Contents