Refitting, SMB unit
Use this procedure to refit the SMB unit.
NoteAction
DANGER
Turn off all:
electric power supply
hydraulic pressure supply
air pressure supply
to the robot, before entering the robot working
area.
1
ELECTROSTATIC DISCHARGE (ESD)
The unit is sensitive to ESD. Before handling the
unit read the safety information in section The
unit is sensitive to ESD on page 31
2
Shown in the figure Location of SMB
unit on page 171.
Connect the battery cable to the SMB unit.
Make sure the lock on the battery cable connect-
or R2.G snaps into place during refitting.
3
Art. no. is specified in Required
equipment on page 171.
Connect all connectors to the SMB board:
R1.SMB1-3, R1.SMB6 and R2.SMB
4
Shown in the figure Location of SMB
unit on page 171.
Fit the SMB unit onto the guide pins.5
Secure the SMB unit to the pins with the nuts
and washers.
6
X9
X8
X10
xx1700000978
If disconnected, reconnect the connectors X8,
X9 and X10 to the brake release board.
Be careful not to damage the sockets or pins.
Make sure the connector and its locking arms
are snapped down properly.
7
Shown in the figure Location of SMB
unit on page 171.
Secure the SMB cover with its attachment
screws.
If cabling is used for 7th axis (option), refit the
7th axis connector to the SMB cover and tighten
with 6 Nm.
8
See Updating revolution counters on
page 356.
Update the revolution counter!9
DANGER
Make sure all safety requirements are met when
performing the first test run. These are further
detailed in the section First test run may cause
injury or damage on page 26.
10
Product manual - IRB 760 173
3HAC039838-001 Revision: M
© Copyright 2011-2018 ABB. All rights reserved.
4 Repair
4.3.3 Replacing the SMB unit
Continued

Table of Contents

Related product manuals