EasyManua.ls Logo

ABB IRB 760 Series - Page 307

ABB IRB 760 Series
402 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
NoteAction
xx1000001103
Refit the cable gland cover at the cable exit with
its two attachment screws.
Note
Use a new gasket!
13
xx1000001102
Refit the motor cover with its attachment screws
and washers.
Note
Make sure the cover is tightly sealed!
14
xx1000001101
Remove the lock screw from the hole for lock
screw.
15
See section Performing a leak-down
test on page 146.
Perform a leak-down test of the axis 2 or 3
gearbox.
16
See section Changing oil, gearbox
axes 2 and 3 on page 129.
Refill the gearbox with oil.17
Continues on next page
Product manual - IRB 760 307
3HAC039838-001 Revision: M
© Copyright 2011-2018 ABB. All rights reserved.