NoteAction
DANGER
Turn off all:
electric power supply
hydraulic pressure supply
air pressure supply
to the robot, before entering the robot
working area.
11
Detailed in section Draining, axes 2 and 3
on page 131.
Note
Time-consuming activity!
Drain the gearbox.12
Remove the motor cables of axis-2 or axis-
3 motor, depending on which gearbox is
being removed. Protect the cables from
getting damaged and from oil spill.
13
Remove one gearbox at a time!14
Detailed in section Replacing motors, axes
2 and 3 on page 298
Remove the axis-2 or axis-3 motor, depend-
ing on which gearbox is being removed.
15
xx1000001405
Remove all remaining attachment screws
that secure the gearbox to the lower arm
system.
Axis 2: M16 and M12.
Axis 3: M12.
16