EasyManua.ls Logo

ABB NGC8206 - ENC82 L Optional Catalytic Heater Installation; Materials; Instructions

ABB NGC8206
239 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page 3–46
2101510 Rev. AG
3.25 ENC82L Optional Catalytic Heater Installation
The following procedures describe the steps for installing a
catalytic heater for the environmental enclosure.
Verify the heater and fittings are approved for the classification
rating of the area of installation.
These instructions are only applicable to the large
environmental enclosure. In the small environmental
enclosure the catalytic heater is already installed.
3.25.1 Materials
Catalytic heater (installed at the factory)
Thermostat assembly with temperature probe
Regulator assembly with shut-off
T assembly
Tubing
Filter/drain assembly
Temperature probe mounting clip
Teflon
®
tape
¼” male pipe connection from external gas source to catalytic heater. Materials
for gas source are not be provided by Totalflow. Quantities and materials to be
determined by the technician based on installation and local codes.
DC power source wiring. Materials for external power source for electrical
preheat wiring are not provided by Totalflow. Quantities and materials to be
determined by the technician based on installation and local codes.
3.25.2 Instructions
1) Locate the installed catalytic heater on the rear of the environmental enclosure
(see Figure 3-47
).
2) Remove the protective end cap from the catalytic heater input fitting, if required.
3) Apply Teflon
®
tape to threads of the male end of the T assembly (see Figure
3-48).
4) Screw the threaded end of the T assembly into the ¼” female fitting located on
the factory-installed catalytic heater, by turning the entire assembly clockwise
until tight (see
Figure 3-49).