Page 6–28
2101510 Rev. AG
6.5.7 AC Charger/Power Supply Troubleshooting Test
If the system setup includes an AC charger/power supply connected to the
optional equipment enclosure, and it is not supplying the required voltage to the
NGC unit, test the AC charger/power supply.
6.5.7.1 Instructions
1) Check the input AC voltage to the enclosure power supply. Be certain the
primary AC voltage is correct.
2) If the primary input AC voltage level is correct, and there is no DC output from
the power supply, replace the F1 charger fuse (see Figure 6-3
).
3) If the fuse is not faulty or there is no charger DC output voltage after replacing
the fuse, replace the AC charger/power supply.
Figure 6-3 AC Charger/Power Supply Wiring
6.6 Troubleshooting Communications
These troubleshooting procedures are applicable to an NGC8200 with an installed
radio in the optional equipment enclosure. Use Figure 6-4
as an aid for
troubleshooting communication problems. The three basic types of radio
communications that can be used between the NGC and a radio receiver are:
RS-232 Communications (see Table 6–4 for pin Configurations)
RS-485 Communications (see Table 6–6 for pin Configurations)
RS-422 Communications (available, but not detailed)
The radio/modem may be powered one of two ways: always on or switched. The
specific system setup will determine what steps are needed to power the
radio/modem.
QUINT POWER
PHOENIX
CONTACT
Input
AC 100-240V
L N
-
-
+
+
DC
OK
DC OK
Adjust
11.5-18V
SERIAL PORT 1
1 2 3 4 5 6 7 8 9
SERIAL PORT 2
1 2 3 4 5 6 7 8 9
1
2
1 2
(+) (-) (+) (-) (+) (-) (+) (-)
INPUTS OUTPUTS
(+) (-)
PWR IN
PWR
5VDC
J10
J8
SECURITY
DIGITAL I/O POWER
S2
RESET
SECURITY
ENABLED
LINK
STAT
LAN
1 2
STATUS
S1
D4D3
D13D11D12
ETHERNET
J7
J3
D2
USB HOST
USB CLIENT
J2
J1
J5
J6
UNSECURE
NGC Termination
Board
(-)
(+)
TERM
NO TERM
TERM
NO TERM
J11
31
J9
31
Enclosure
100/120 VAC
13
14
Output DC 12V 10A

Table of Contents

Related product manuals