Note/IllustrationAction
Location of wrist strap button:
ELECTROSTATIC DISCHARGE
(ESD)
When handling the computer outside of
the controller, use the wrist strap button
located on the side of the computer.
2
xx2100001295
Reconnect:
A2.X9 - T4.X3
A2.X10 - T4.X1
A1.X6 - A2.X11
A1.X13 - A2.X12
A2.X13 - G1/G2.X1
3
Concluding procedure
Note/IllustrationAction
Refitting the controller cover on page 121.Refit the top cover.1
Restoring the hardware settings on page 145.Restore the hardware settings.2
Perform the function tests to verify that
the safety features work properly, see
Function tests on page 110.
3
Restoring the hardware settings
The controller hardware settings include information such as controller type and
serial number. When the computer and logic unit has been replaced, the serial
number must be restored before any software can be installed, or any licences
can be imported.
Note
When replacing the computer and logic unit, both the serial number and licences
are lost. The serial number must be restored as described below. Licences
however, can either be restored automatically when the RobotWare system is
installed, or manually through Manage Licences in RobotWare Installation
Utilities.
Note/IllustrationAction
Download the hardware information file
(hwsettings.rsf) from MyABB, or from a
previous system backup.