Chapter 3. Configuration
3-12 MX2800 User Manual 61200290L1-1
XCV Threshold
Set a limit on code violations (CVs) accepted by the unit over an
individual T1/E1 line before it switches controller cards. If set to
D
ISABLED
, code violations will not cause the unit to switch
controller cards. The threshold limits are described in the following
chart:
SYSTEM MANAGEMENT
Configure the MX2800 for management through SNMP, Telnet, or a
VT 100 interface (see Figure 3-12). Embedded SNMP and Telnet are
available via a SLIP/PPP modem port or 10BaseT ethernet
interface. This menu also includes options used to customize your
unit’s alarm and trap generation, security setup, and equipment
identification.
Figure 3-12. System Management Configuration Menu
Setting The unit switches controller cards if...
1E
-3
more than one out of every 1,000 bits received on a
T1/E1 line contains a code violation.
1E
-4
more than one out of every 10,000 bits received on a
T1/E1 line contains a code violation.
1E
-5
more than one out of every 100,000 bits received on a
T1/E1 line contains a code violation.
1E
-6
more than one out of every 1,000,000 bits received on
a T1/E1 line contains a code violation.