Chapter 3. Configuration
3-20 MX2800 User Manual 61200290L1-1
Power Supply Alarm Traps
Trap If enabled, the unit issues a trap when...
Card Removed the power supply card has been removed.
Malfunction the power supply card is no longer working and
the unit has switched to the backup power sup-
ply or battery backup.
Card Failure the power supply card has failed.
Power Low the power supply’s output level is abnormally
low.
Charger Fail the battery backup charger has failed or has
lost its AC connection.
Battery Low the battery backup has reached a critical ener-
gy point at which it may be unable to supply the
unit with sufficient power to maintain operation.
Temperature
High
the power supply card is getting too hot.
Temperature
Critical
the power supply card temperature is so high
that it will soon shut off completely.