6TANTP501-1E
TOTAL ACCESS 3000/3010
NTP-501
Page 18 of 22
© 2002, ADTRAN, Inc.
Total Access
®
3000/3010 System Manual
1.14.7 Set Host Mode if Applicable
NOTE
If the Total Access 3000/3010 shelf is to be installed as a stand alone unit, not
connected to any other Total Access shelf via the RS-485 bus, then the
Interbank Communication Mode can be set to either Host or Client. Skip the
remainder of this procedure and continue to 1.14.8.
When assembling a daisy chain for management of up to 16 shelves from a single craft
interface, one single SCU is designated as the host and all others on the chain are
designated as clients.
NOTE
Only one SCU can be designated Host in any daisy chain composed of Total
Access shelves connected on the RS-485 bus. The Host SCU must be the end
SCU on the chain. It does not matter which end has the Host SCU, but the Host
cannot be in the middle of the daisy chain. It is recommended that the Host
SCU be the first in the chain.
To back up one step from anywhere in the menu tree on the Total Access screens,
press <Esc>.
Other helpful commands are:
Backspace Delete character to left
Enter (or Return) Terminate Input
Control-R Re-display screen
Control-X Terminate Aux shelf connection (if active)
Control-Z Return from Access module menus to SCU menu
Esc Clear partial input data, or if none, return to previous
menu