The DSX-1 module also supports a full range of diagnostic alarms and loopbacks to
aid in troubleshooting. Payloads can be looped back toward the network or customer.
Loopbacks toward the customer have an optional framing regeneration feature, which
allows the payload to have the embedded framing regenerated or not.
The DSX-1 module incorporates these features:
• Supports standard T1 MIB 1406 for alarm states
• AMI or B8ZS line coding
• SF, ESF and Unframed framing formats
• Automatically switches to online MUX module upon MUX failure or
removal
• Automatically switches to local timing if LOS is detected from customer
The faceplate LED indicators include:
•PWR
• NTWK
• TST
• DSX
• ALM
Other faceplate features include:
• DSX-1 bantam jacks.