102
12.3 Poor performance at high speed
N.G.
O K
N.G.
Fuel Flow
Restricted
O K
clogged
O K
Dirty
Check Ignition Timing
Possible cause
Faulty CDI unit or Pulse generator
Check Fuel Flow to Carburetor
Lack of fuel in tank
Clogged fuel line
Clogged fuel valve
Clogged fuel filter
Clogged fuel tank breather hose
Remove Carburetor check
for clogged jets
Clean jets with high pressure air gun
Check Air
Clean Element
Clean or Replace air clean element
N.G
N.G