EasyManua.ls Logo

Agilent Technologies 8648A

Agilent Technologies 8648A
481 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8-13
Performance Tests
FM Distortion Performance Test
FM Distortion Performance Test
Connect the Test Equipment
Figure 8-5. FM Distortion Equipment Setup
Configure the Measuring Receiver
1. Reset
2. FM mode
3. Peak+ detector
4. 300 Hz high-pass filter
5. 15 kHz low-pass filter
Configure the Audio Analyzer
1. Distortion mode
2. 30 kHz low-pass filter
Configure the 8648
1. Turn FM on; press FM MOD ON/OFF.
2. Set the rate; press
INT 1 kHz.
3. Set the amplitude; press
AMPLITUDE 4 dBm.
4. Turn the RF output on; press
RF ON/OFF.

Table of Contents

Other manuals for Agilent Technologies 8648A

Related product manuals