Agilent Triple Quadrupole LC/MS System
User Guide

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Agilent Technologies Triple Quadrupole LC/MS and is the answer not in the manual?

Agilent Technologies Triple Quadrupole LC/MS Specifications

General IconGeneral
BrandAgilent Technologies
ModelTriple Quadrupole LC/MS
CategoryLaboratory Equipment
LanguageEnglish

Summary

Notices

Safety Notices

Provides information on CAUTION and WARNING notices for safe operation and potential hazards.

In This Guide

Additional Resources

User Documentation

Information on data analysis and library management documentation, accessible via code or URL.

Technical Support

1 Introduction

Agilent Regulatory Compliance Statement

Details compliance with EU and UK regulations like EMC, LVD, MD, and RoHS directives.

2 Hardware Overview

Ultivo Triple Quadrupole LC/MS

Overview of the Ultivo LC/MS system, including front and rear views and calibrant delivery.

6475A Triple Quadrupole LC/MS

Overview of the 6475A LC/MS system, covering front and side views and calibrant delivery.

6495D Triple Quadrupole LC/MS

Overview of the 6495D LC/MS system, detailing front and side views and calibrant delivery.

Ion Sources

Electrospray Ionization (ESI) source

Explanation of the Electrospray Ionization (ESI) source and its operation.

Agilent Jet Stream (AJS ESI) source

Details on the Agilent Jet Stream (AJS ESI) source, its technology, and benefits.

Atmospheric Pressure Chemical Ionization (APCI) source

Description of the Atmospheric Pressure Chemical Ionization (APCI) source.

3 Tuning

About Tuning

Explains the purpose of tuning the MS to optimize sensitivity, resolution, and mass assignments.

Autotune and checktune

Describes the procedures for autotune and checktune to verify instrument performance.

Calibrating the LC/TQ (Checktune)

Procedure for performing a checktune on the LC/TQ instrument.

4 Basic Operation

Overview

Provides a roadmap for setting up and running a batch of samples.

Starting Up and Shutting Down the Instrument

Instructions for starting the instrument in standby mode and shutting it down.

Starting the MassHunter Data Acquisition Software

Steps to start the MassHunter Data Acquisition program.

MassHunter Data Acquisition windows

Instrument Status window

Displays the status of each device configured with the instrument (e.g., Error, Idle, Running).

Method Editor window

Window for entering acquisition parameters for the method.

Setting Up an Acquisition Method

5 Maintenance

Maintenance Overview

Importance of instrument servicing and maintenance for optimal performance and accuracy.

Routine Tasks

Procedures for daily and weekly routine maintenance tasks.

Periodic Tasks

Procedures for periodic maintenance tasks, including pump oil checks and replacements.

General Maintenance Tasks

Procedures for general maintenance like installing/removing nebulizers and capillaries.