20
4. Datasheet
RO Inline™ 300 RO Inline™ 500RO Plus™ l RO Plus™ ll RO Plus™ lll RO Basic™
Water capacity, up to, l/h
at 15 °C/3 bar or 59 °F/44 psi supply pressure
300 600 900 90 at 3 bar / 44 psi
180 at 7 bar / 102 psi
300 500
Membranes, pce 1 2 3 1 1 2
Power supply V AC
230/240 V, 50/60 Hz is always 1P+N+PE
3x400/230 to 480/240 V, 16 Amp
3P + N + PE
230V, 13 Amp
1P + N + PE
230V, 13 Amp
1P + N + PE
Operating voltage range V AC ± 10 % ± 10 % ± 10 %
Frequency Hz
60 Hz is non standard
50/60 50/60 50/60
Membrane pressure pump kw 1,5 - 0,75
Booster supply pump kw 0,5 0,5 -
Max. eect kw 2,0 0,5 -
Supply water pressure bar/psi 2-7 / 29-101,5 3-7 / 43,5-101,5 2-7 / 29-101,5
Supply water connection 3/4” 3/4” 3/4”
Membrane operating pressure range bar 10 - 13 (max. 15) 3 - 7 (max. 7) 10 - 13 (max. 15)
Alarm out, potential free
Stabilized salt rejection.
with 2000 mg/l NaCl at 25 °C/10 bar
Up to 98% Up to 98% Up to 98%
Vessel pressure range, bar - - 2 to 6 (default 2 to 5)
Hysteresis range - - 1 - 4 (default 3) bar
Outlet pressure bar 1,5 - 3,5 1,5 - 3,5 Min. vessel pressure - 1
Drain ush - with softener
- without softener up to 15 °dH
> 30 %
> 50 %
> 30 %
> 50 %
> 30 %
> 50 %
Temp. range °C/°F 1-20 (35) / 34-68 (95) 1-20 (35) / 34-68 1-20 (35) / 34-68
Noice level dB (A) < 70 < 70 < 70
Dimensions (width x depth x height) 720 x 600 x 1835 mm
28,5” x 23,6” x 72,3”
510 x 400 x 1650 mm
20,0” x 15,8” x 65,0”
incl. 200 mm / 8” elevation
695 x 380 x 1255
mm
27,4” x 15,0” x 49,4”
845 x 380 x
1255mm
33,3” x 15,0” x 49,4”
Weight kg/lbs
Weight incl. water in vessel kg/lbs
182 / 401
-
193 / 426
-
240 / 529
-
32 / 71
-
69 / 52
89 / 196
86 / 190
106 / 234
Protection class IP 53 53 52
Water tank incl. base
Volume, l 125 300 600 125
Dimensions (width x depth x height) mm 570 x 570 x 1100
22,5” x 22,5” x 44”
750 x 750 x 1200
29,5” x 29,5” x 47,3”
750 x 750 x 1800
29,5” x 29,5” x 71”
570 x 570 x 1100
22,5” x 22,5” x 44”
Weight, kg 14 25 37 14
Temperature range °C/°F 1-20 (35) / 34-68 (95) 1-20 (35) / 34-68 (95)
4.6 Reverse osmosis