10. Spare Parts Lists & Recomandations
10.10 Sensor
Part no. Description Recommendations
121100 Sensor, SmartSens 3000 Replace if oset > ±5%
10.9 HydroSens / pump unit
Part no. Description Recommendations
Recommended minimum, once every
12 months 24 months 36 months 48 months 60 months
161710 1/8” Non return valve
6.000 h
161752 1/8” Non return valve complete (EL, HL, HS)
531084 Relief valve for drain
3.000 h
365777 Relief valve for drain (HS)
211128 Solenoid valve kit 3/2
6.000 h
211110 Solenoid valve 3/2
12.000 h
201435 Sealing kit pump 200 l/h (NP10/4)
3.000 h
201430 Sealing kit pump 600/800 l/h (NP10/10, 10/15)
201432 Sealing kit pump 1200 l/h (NP16/21)
201420 Valve kit pump 200-1200 l/h (NP10, NP16)
9.000 h
201310 Pump 600 l/h
15.000 h
201320 Pump 800 l/h
201340 Pump 1200 l/h
201410 By-pass 200-800 l/h (NP10)
15.000 h
Nyt nr By-pass 1200 l/h (NP16)
365325 Electrical motor complete 1,1 kW
Change with pump 15.000 h
365378 Electrical motor complete 1,5 kW
365382 Electrical motor complete 2,2 kW
231250 Filter for control unit
365425 Relay for ventilator start/stop (HL, EL, HS)
3.000 h
201218