8. Service
Check the non return valve. • Close the outlet ball valve.
• Check that the pressure vessel can maintain the pressure after production
stop . The pressure will drop < 0,3 bar immediately after stop.
- if the pressure drops further, replace the non return valve
ESC+C.. 9/9
~
| }
Read hours and counters. • Go to the maintenance menu - password 9963.
- Read operating hours.
- Read pump hours.
- Read alarm counters and power on/off counter.
- Reset alarm counters and power on/off counter.
-Hours-
System XXXXXX
Pump XXXXXX
S.Ser vice XXXXXX
-Log-
PowerUp XXXXXX
No Water XXXXXX
External XXXXXX
Temp.Motor XXXXXX
Low Prod. XXXXXX
Low Drain XXXXXX
Fault K1 XXXXXX
Service Info.
Show
1
Reset = Set to 1
Service 0
Log. 0
Check for leaks. • Check all connection are tight.
• Leave it for 10 min and come back all should be dry.
Check UV light. • Shut down booster pump.
- On the fuse in RO control.
• Untighten the fitting that holds the UV light in place.
• Lift the lamp out carefully.
• Check that the lamp is still active.
• This lamp should be replaced every 12 month.
• Reassemble and start the pump again.
•
This type of light contains mercury, dispose of accordingly to local rules.
Fill in AirtecCare checklist 4.1 - 4.16.
201218