TROUBLESHOOTING
44 Compressor intake temperature ( )
45 Accumulator outlet temperature (
)
46 Compressor 1 discharge pipe temperature (
)
47 Compressor 2 discharge pipe temperature (
)
49 Outdoor heat exchanger vapor pipe temperature (
)
4A Outdoor heat exchanger liquid temperature (
)
4b Outdoor liquid pipe temperature (
)
4c Sub heat exchanger liquid temperature (
)
4d Outside air temperature (
)
50 Engine compartment temperature (
)
51 Engine coolant temperature (
)
53 Engine exhaust air temperature (
) unit with deodorant kit only
54 Starter voltage (0.1 V)
55 Igniter voltage (0.1 V)
56 Starter transformer voltage (0.1 V)
60 Engine running hours (hours) ●●
Unit in check mode: hours/10
61 Last periodical inspection time (hours) ●●
Unit in check mode: hours/10
62 Compressor 1 running hours (hours) ●●
Unit in check mode: hours/10
63 Compressor 2 running hours (hours) ●●
Unit in check mode: hours/10
68 Number of starter on/off times (times) ●●
Unit in check mode: times/100
69 Number of Engine on/off times (times) ●●
Unit in check mode: times/100
6A Number of compressor 1 on/off times (times) ●●
Unit in check mode: times/100
6b Number of compressor 2 on/off times (times) ●●
Unit in check mode: times/100
70 Serial code Factory default setting
71 Model code Factory default setting
72 OEM code Factory default setting
73 Model type (multi) Factory default setting
74 Outdoor unit series and capacity (0.1 kW) Factory default setting
75 Additional function Factory default setting
78 Main microcomputer programming version
79 Engine microcomputer programming version
7A IF microcomputer programming version
7b Periodical inspection ●●
Check of periodic inspection
time / periodic inspection reset
80 EEPROM dip switch 1 ◎◎
81 EEPROM dip switch 2 ◎◎
82 EEPROM dip switch 3 ◎◎
83 EEPROM dip switch 4 ◎◎
84 EEPROM dip switch 5 ◎◎
85 EEPROM dip switch 6
98 Tc set value (
)
99 Te set value (
)
Code No. Functions Monitor Command Check Remark
: Available for only master unit., : Available for both master and dependent units., : Available for both master and dependent
units, although some functions are not available for dependent unit.
: Not available when maintenance checker is connected. (No code is available in check mode.)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AISIN SEIKI E1 Series and is the answer not in the manual?

AISIN SEIKI E1 Series Specifications

General IconGeneral
BrandAISIN SEIKI
ModelE1 Series
CategoryAir Conditioner
LanguageEnglish