EOW interfaces
...................................................................................................................................................................................................................................
Purpose
An Engineering Order Wire (EOW) can be connected to these interfaces.
NOTE: The EOW interfaces are only available on1643 AMS units.
Connector data
The two EOW connectors are 15-pin SUB-D male connectors (hotshrinked tailed).
They provide V.11 data channels with a bit rate of 64 kbit/s.
Table 4-10 Pin assignment (EOW cables, valid for both connectors)
Point on Connector Signal Name
1 GND
2 V11RCP
3 V11RSP
4 V11RDP
5 V11TCP
6 V11TSP
7 V11TDP
8 GND
9 V11RCN
10 V11RSN
11 V11RDN
12 GND
13 V11TCN
14 V11TSN
15 V11TDN
Cable data
Preferably, a symmetrical 100 Ω cable (8xSTP) should be used.
Figure 4-32 EOW connector
1
9
8
15
System cabling
...................................................................................................................................................................................................................................
4-30
Alcatel-Lucent - Proprietary
See notice on first page
365-312-802R7.2