SUB-D connector
...................................................................................................................................................................................................................................
Description
The amphenol metallic hoods for SUB-D connectors protect cable assemblies from
magnetic and radio interferences.
These hoods are easily assembled and suitable for all industrial and telecom
applications.
Assembly instructions
Please observe the following SUB-D assembly instructions:
...................................................................................................................................................................................................
1
Important! Protect the braid by stripping.
Strip the cable as necessary.
...................................................................................................................................................................................................
2
Prepare the braid as shown in Figure C-1, “SUB-D assembly steps” (p. C-3).
...................................................................................................................................................................................................
3
Solder the wires to the pin contacts.
...................................................................................................................................................................................................
4
Put the ferrules around the braid on the cable.
Important! Shape the strands of braid into two pigtails and bend these pigtails
back 180 degrees over the ferrule.
...................................................................................................................................................................................................
5
Insert the cable with the ferrule into the SUB-D connector.
...................................................................................................................................................................................................
6
Close the connector by tightening the screws.
Cable assembly instructions
...................................................................................................................................................................................................................................
C-2
Alcatel-Lucent - Proprietary
See notice on first page
365-312-802R7.2
Issue 4, June 2007
E ND OF STEPS
...................................................................................................................................................................................................