Table 4-18 Optical specifications (continued)
S1.1 S1.1 (18dB) L1.2 S4.1 L4.2
Max. output
power
–8...–15 dBm –8...–15 dBm +0...–5 dBm –8...–15 dBm +2...–3 dBm
Eye mask pattern see G.957 see G.957 see G.957 see G.957 see G.957
FDA class/IEC
hazard level
Class I/1 Class I/1 Class I/1 Class I/1 Class I/1
Maximum
dispersion
185 ps/nm 185 ps/nm not applicable 74 ps/nm not applicable
Attenuation range 0...12 dB 0...12 dB 10...28 dB 0...12 dB 10...24 dB
Optical path
penalty
<1dB <1dB <1dB <1dB <1dB
Receiver
Sensitivity –28 dBm
min.
–34 dBm min. –34 dBm min. –28 dBm
min.
–28 dBm min.
Overload –8 dBm
max.
–8 dBm max. –8 dBm max. –8 dBm
max.
–8 dBm max.
Connector/Fiber type
Connector type SC, FC, ST SC, FC, ST SC, FC, ST SC, FC, ST SC, FC, ST
Fiber type
core/cladding
diameter (µm)
SM (9/125) SM (9/125) SM (9/125) SM (9/125) SM (9/125)
NOTE: It is not mandatory to have an LBO (Lightguide Build-Out) between the optical
interfaces of the 1643 AM unit and the connected optical cable. However, in the case
of measurements with optical loops and/or connecting power meters an LBO (15 dB)
can be required. An LBO can also be necessary to ensure the correct input power (see
chapter 8, section “Connecting the fiber cables” (p. 8-2)).
System cabling
Optical interfaces (AM unit)
....................................................................................................................................................................................................................................
365-312-802R7.2
Issue 4, June 2007
Alcatel-Lucent - Proprietary
See notice on first page
4-51