Management state
The state of the association with the OMS is displayed. The possible states are
described in the table below.
Management state Description
Normal Normal will be displayed whenever the automated management
operations have been completed. In other words, the OMS has
completed the MIB upload, MIB download, MIB
resynchronization, or reevaluation of fault status. The state can
also be Normal when the association between the
ITM-CIT/OMS and the NE has been lost.
Uploading The OMS is performing an MIB upload.
Resyncing If the MIB of the NE and the MIB image on the OMS are out
of synchronization, then the OMS invokes a resynchronization.
The management state shows the progress of this operation. If
executed properly, it should display, in order: Normal,
Resyncing, Normal, ReEvaluatingFaultStatus, Normal.
ReEvaluating
FaultStatus
After a resynchronization, the OMS initiates a reevaluate fault
status operation.
Downloading A MIB download has been started by the OMS. The
management state is set to Normal during the downloading
process. If the MIB download is in progress when a loss of
association occurs, then the management state will remain
Downloading.
EMS connection state
Indicates wether an active connection (CMISE association) exist to the element
manager (OMS).
ITM-CIT installation and NE provisioning
Confirm/Update the MIB
....................................................................................................................................................................................................................................
6-24