EasyManua.ls Logo

Alcatel-Lucent 1643 AMS - Page 201

Alcatel-Lucent 1643 AMS
278 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Note: Subtract 0.50 dB per optical connection (for the suggested set-up 1.5 dB (3
connections)) and subtract 0.2 dB per fiber segment (0.4 dB for 2 fiber segments).
...................................................................................................................................................................................................
12
Disconnect the optical power meter and reconnect the fiber to the receive port of
LP1.1.
...................................................................................................................................................................................................
13
Remove the optical loop from the ODF and install a variable optical attenuator.
...................................................................................................................................................................................................
14
Increase the attenuation until the PDH analyzer reports single bit errors.
...................................................................................................................................................................................................
15
Decrease the attenuation a little until no errors are reported.
...................................................................................................................................................................................................
16
Wait approximately 5 minutes (no errors may occur).
...................................................................................................................................................................................................
17
Disconnect the fiber from the Line Port “input” at the physical NE port and measure
the optical output level (refer to Figure 7-2, “Line port connection to optical
distribution frame test” (p. 7-9)).
...................................................................................................................................................................................................
18
Verify that the requirements mentioned in the table below are met.
Result:
Receiver sensitivity ranges:
Interface Wavelength [nm] Receiver sensitivity [dBm]
S1.1 1310 –28
S1.1 (18 dB) 1310 –34
S4.1 1310 –28
L1.1 1310 –34
L1.2 1550 –34
L4.2 1550 –28
...................................................................................................................................................................................................
19
Repeat test for Line Port 2.1, if applicable.
Stand-alone test procedures
Line port connection to optical distribution frame test
...................................................................................................................................................................................................................................
365-312-802R7.2
Issue 4, June 2007
Alcatel-Lucent - Proprietary
See notice on first page
7-11
E ND OF STEPS
...................................................................................................................................................................................................

Table of Contents

Other manuals for Alcatel-Lucent 1643 AMS