6 — 9500 MPR/9500 MPRe shelf object configuration
Alcatel-Lucent 5620 Service Aware Manager, Release 11.0 R5 September 2013 6-9
3HE 08459 AAAA TQZZA Edition 01
MPR User Guide
4 Right-click on the port that you associated with the MW link and choose
Properties. The MW Link Member (Edit) form opens with the General tab
displayed.
5 Configure the parameters, if required:
Radio Name
StandAlone
Database Filename
6 Click on the Radio tab.
7 Configure the parameters, if required:
Radio Transmit State
Reboot
8 Click on the OK button. A dialog box appears.
9 Click on the Yes button. The MW Link Member (Edit) form closes.
Note 1 — For migration, restart the MPT using the MCT and deselect
the Standalone check box within 30 to 60 s of the radio restart or the
MPT may not function as expected. If the restart fails to change the MPT
to single NE mode, the MPT must be physically restarted.
Note 2 — You can use the MCT only if the 9500 MPRe is in standalone
mode and managed by the 5620 SAM. If the 9500 MPRe is connected to
the 7705 SAR in standalone mode, but not managed by 5620 SAM, you
must use the NEtO/MCT.