11 — 9500 MPR VLL service management
Alcatel-Lucent 5620 Service Aware Manager, Release 11.0 R5 September 2013 11-9
3HE 08459 AAAA TQZZA Edition 01
MPR User Guide
24 Perform one of the following:
a Create an another site for the VLL service, if required. Repeat steps 11
to 21 .
b Complete service creation.
25 Click on the OK button. The Cpipe Service (Create) form closes.
You can use the service topology maps to view the service.
Procedure 11-3 To fix a failed cross-connection in a 9500 MPR VLL
Cpipe service
The 5620 SAM may fail to establish one or more cross-connects when you deploy a
9500 MPR Cpipe service, or a cross-connect may fail after the service is created. If you
determine that a service is down because of a failed cross-connect, you can try to
re-establish the cross-connect.
1 Choose ManageServiceServices from the 5620 SAM main menu. The Manage
Services form opens.
2 Configure the filter criteria for the service type that you need to find and click on
the Search button. A list of services appears.
3 Choose a 9500 MPR Cpipe service and click on the Properties button. The Cpipe
Service (Edit) form opens with the General tab displayed.
4 Click on the Complete Service button. A dialog box appears.
5 Click on the Yes button.
6 Verify that the cross-connects are operational.
7 Close the Manage Services form.
Note — If service creation fails or generated NE inconsistencies occur,
see Procedure 4-2.
Note — You must clear deployment errors that are associated with a
failed cross-connect before you attempt to re-establish the
cross-connect.