11 —  9500 MPR VLL service management
11-8 September 2013 Alcatel-Lucent 5620 Service Aware Manager, Release 11.0 R5
3HE 08459 AAAA TQZZA Edition 01
MPR User Guide
13 Configure the parameters:
• Name
• Description
• Administrative State
• Monitor Access Interface Operational State
14 Click on the Components tab.
15 Right-click on L2 Access Interfaces and choose Create L2 Access Interface. The L2 
Access Interface (Create) form opens with the General tab displayed.
16 Configure the parameters:
• Name 
• Description
17 Click on the Port tab.
18 Click on the Select button to choose a port for the L2 access interface. The Select 
Terminating Port - L2 Access Interface form opens.
19 Use the configurable filter and Search button to choose a port, and click on the 
OK button. The Select Terminating Port - L2 Access Interface form closes, and the 
L2 Access Interface (Create) form displays the port information.
20 Click on the OK button. A dialog box appears.
21 Click on the OK button. The L2 Access Interface (Create) form closes, and the 
Cpipe Site (Create) form reappears with the new interface information displayed 
in the service navigation tree.
22 If the 9500 MPR Cpipe service is for an ERPS tail node, a radio or Ethernet 
termination port is required for the site:
i Click on the Tail Terminating Port tab.
ii Click on the Select button to choose an ERPS tail terminating port. The Select 
ERPS Tail Terminating Port - Cpipe Site form opens.
iii Choose an ERPS tail terminating port and click on the OK button. The Cpipe 
Site (Create) form reappears.
23 If you need to create another L2 access interface for the site in the Cpipe service, 
repeat steps 15 to 21.
Note —  The form lists only ports in access or hybrid mode. To choose 
a port that is not listed, you must set the Mode parameter for the port 