12 Repeat steps 8 to 11 to configure more ports for housekeeping alarms, as required.
13 Click on the OK button. A dialog box appears.
14 Click on the Yes button. The Fan Tray (Edit) form closes.
Procedure 6-4 To configure 9500 MPR card protection
The 9500 MPR supports card protection for all card types. EPS card protection for the
CORE-ENH card in slot 1 is automatically configured by the system when an optional
spare CORE-ENH card is provisioned into slot 2. Radio modem and 32 x DS1/E1 cards in
slots 3, 5, and 7 can be protected by corresponding identical cards in slots 4, 6, and 8.
Protection for cards in slots 3, 5, and 7 must be configured. The protected card is
referred to as the main card and the protecting card is referred to as the spare card.
Use the following procedure to configure optional card protection for radio modem and
32 x DS1/E1 cards.
1 Choose Equipment from the navigation tree view selector. The navigation tree
displays the Equipment view.
2 Right-click on the 9500 MPR object and choose Properties from the contextual
menu. The Network Element (Edit) form opens with the General tab displayed.
3 On the Network Element (Edit) form navigation tree, expand the Shelf object.
4 Click on the card slot object that you need to configure. The Card Slot (Edit) form
opens with the General tab displayed.
5 Click on the Protection tab.
6 Configure the following parameters on the main/spare card:
• Protection Type
• Restoration Criteria
• Commands
7 Click on the OK button. A dialog box appears.
8 Click on the Yes button. The Card Slot (Create) form closes.
9 Verify that the protection is enabled. The status of the main card should be Active
and the status of the spare card should be Standby.
Note 1 — All cross connections, flow-IDs, and synchronization sources
must be removed from the port under the spare card slot before
protection can be enabled.
Note 2 — To configure protection type 1+1 FD on Radio, the Mode