7 — 9500 MPR/9500 MPRe port object configuration
Alcatel-Lucent 5620 Service Aware Manager, Release 11.0 R5 September 2013 7-11
3HE 08459 AAAA TQZZA Edition 01
MPR User Guide
7 Double-click on a port. The Auxiliary Input - auxIn [Edit] form opens.
8 Configure the parameters:
User Label
Polarity
9 Click on the OK button to apply the changes.
10 Click on the External Point Outputs tab.
11 Double-click on a port. The Auxiliary Output - auxOut [Edit] form opens.
12 Configure the parameters:
User Label
Polarity
External State
13 Click on the OK button to apply the changes.
14 Optionally, click on the Aux Card Specifics tab or IO Card tab to display more
read-only AUX alarm card properties.
15 Click on the OK button to apply the changes and close the Card Slot [Port Number],
AUX, Shelf (Edit) form.
Procedure 7-7 To configure a 9500 MPRe port
Perform this procedure to configure the OLC parameters and administrative state of a
9500 MPRe port. All other radio port parameters must be configured using the MCT.
1 Choose Equipment from the navigation tree view selector. The navigation tree
displays the Equipment view.
2 Expand the 9500 MPRe icon to the port level and click on a port object. The
Physical Port (Edit) form opens with the General tab displayed.
3 Right-click on the device where you need to configure a 9500 MPRe port and
choose Properties from the contextual menu. The Network Element (Edit) form
opens with the General tab displayed.
4 Configure the Current OLC State and Revert OLC State parameters.
5 Click on the OK button. A dialog box appears.
6 Click on the OK button. The Physical Port (Edit) form closes.