EasyManuals Logo

Alcatel-Lucent OmniPCX Enterprise User Manual

Alcatel-Lucent OmniPCX Enterprise
108 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #34 background imageLoading...
Page #34 background image
OmniPCX Enterprise
INSTALLATION PROCEDURE FOR VERSION
J1.410.34.c – RELEASE 10.0
TC1449 34 Ed. 02 / 22 June 2011
Note
The "Load Balancing" mode is supported by these models.
In migrating a system with Appliance Server from a release less than 8.0, check that it has 1 GB of
memory. Otherwise, additional memory has to be ordered through an IBM reseller and installed on
the Appliance Server.
IBM X306:
http://www-03.ibm.com/systems/xbc/cog/Withdrawn/x306/x306mem.html
IBM X306m:
http://www-03.ibm.com/systems/xbc/cog/Withdrawn/x306m/x306mmem.html
7.7.4 Hard disk capacity
A hard disk with a minimum of 10 GB must be used.
7.7.5 USB keys compliant with CPU7-2, Appliance Server and Blade Server
USB keys, for save and restore on USB key, are compatible as of Release 7.1 with CPU7-2,
Appliance Server and Blade Server only. The USB connector of CS-2 CPU board is unused.
Note
Hard disk on USB is not supported.
7.7.6 IO2 board
The IO2 and IO2N boards must be flashed with a boot of at least version 4.0.
7.7.7 INTIP board
The term INTIP concerns INTIP boards as well as INTIP2.
Since Release 5.0 Ux, the INTIP board can be used either in full duplex or in half duplex.
As of Release 5.1, direct RTP is possible with INTIPs.
Since Release 4.2, the INTIP board is multi-functional: IP Phones, Remote IP and VoIP link.
The functioning with a LIOE board is not authorized.
As soon as the migration is completed, you should set the IP services so that the new services
provided by the INTIP board since R4.2 can be used; refer to the System documentation.
The INTIPB board can function at 100 Mbits in all types of shelves. For VH and WM1 cabinets, the
operation depends on the version used; see the table below.
The INTIP board does not function with LIOP/B/X COMP6 in a single network.
Transit is possible between INTIP - LIO P/B/X COMP2.
The INTIP board can not be used with the Ethernet embedded (a CBC1 10/100 connector must be
used).
The CBCA connectors of the LIOE board should not be used to connect an INTIP
board.
The INTIPA board can be used at 100 Mbits. With a VH, it is essential to use the Patch Panel 10/100
Mbits Reference 3BA23244 AAAA 01.

Table of Contents

Other manuals for Alcatel-Lucent OmniPCX Enterprise

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Alcatel-Lucent OmniPCX Enterprise and is the answer not in the manual?

Alcatel-Lucent OmniPCX Enterprise Specifications

General IconGeneral
VoIP ProtocolsSIP, H.323
TypeIP PBX
VoIP CodecsG.711, G.729
IntegrationCRM
SecurityTLS, SRTP
ManagementWeb-based management
RedundancyYes, with redundant CPU and power supply

Related product manuals