INSTALLATION PROCEDURE FOR VERSION
J1.410.34.c – RELEASE 10.0
Ed. 02 / 22 June 2011 55 TC1449
16.1.5 Time-outs (from R3.0)
Control the value of time-out 144 (Timeout for distributed call). It must be greater than or equal to
600.
Control the value of time-out 188 (Timer for Release of set reserved by attendant). It must be greater
than 3000; time-out used for defending sets blocked on networked music on hold.
16.1.6 Accounting (from R3.0)
Access path : Applications/Accounting
Manage all the new parameters according to client requirements.
16.1.7 Filter table (from R3.0)
In order for the attendant not to by-pass filtering, enter the attendant individual call prefix in the filter
tables. Do not enter the attendant physical directory number.
16.2 Reminder for networked sites migrating from Release < 7.x
As of Release 7.0, a new feature is used to display the names with UTF-8 format (long names and
for non Latin languages: Chinese, Korean, Japanese).
In ABC-F2 network functioning, Release 10.0 is also used to send the name with UTF-8 format in the
network according to the setting of the Enable UTF8 in ABCF network system parameter
(default value True).
This information is accepted only from the following versions:
R6.2 : F3.301.16.e (patch for compatibility UTF-8)
R6.1.1 : F2.502.12.d (patch for compatibility UTF-8)
R6.0.1 : F1.603.1.aa (patch for compatibility UTF-8)
If Release 10.0 is functioning in ABC-F2 network with nodes the versions of which are lower than
those mentioned previously (case of temporary phase of migration with R5.0 Ux, R5.x, R6.x), you
must set the Enable UTF8 in ABCF network system parameter to False on Release 10.0
nodes otherwise the calls through the network don't work.
In a network, if a Release 10.0 node is of XL or "Large Capacity" type, each node of
the network must be in Release 8.x.
The system parameter Direct RTP must be enabled in all nodes of the sub-network as soon as
one node is migrated to Release 10.0.
16.3 Additional management for IO2N
For CPU6 equipped with IO2N board, the management of signaling channel for ACT0 only must be
as follows:
Signaling mode = IO2 instead of Nx64

Table of Contents

Other manuals for Alcatel-Lucent OmniPCX Enterprise

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Alcatel-Lucent OmniPCX Enterprise and is the answer not in the manual?

Alcatel-Lucent OmniPCX Enterprise Specifications

General IconGeneral
VoIP ProtocolsSIP, H.323
TypeIP PBX
VoIP CodecsG.711, G.729
IntegrationCRM
SecurityTLS, SRTP
ManagementWeb-based management
RedundancyYes, with redundant CPU and power supply

Related product manuals