INSTALLATION PROCEDURE FOR VERSION
J1.410.34.c – RELEASE 10.0
APPENDIX 1
NEW HARDWARE AND FEATURES
Ed. 02 / 22 June 2011 3 TC1449
1. INTRODUCTION
Consult the Marketing documentation available on Business Portal.
REMINDER
The main features included in previous releases are detailed in the technical communication TC0780
New hardware and features from Release 5.1.
2. NEW HARDWARE AND FEATURES FROM RELEASE 10.0
For more information, refer to the System documentation.
2.1. New hardware
2.1.1. eZ32-2 board
The new eZ32-2 boards are only supported from Release 10.0.
Allow the user to connect up to 32 Z devices (Analog sets or modems or fax machines).
Provide a new method to activate the MWI called DC Bias: Short ringing 100 VDC pulses
(<100 ms) are sent over a and b wires to drive the MWI.
Provide a new service - Calling Party Control [CPC] also called the Open Loop Disconnect
signal.
eZ32-2 boards can provide a CPC signal to terminals. The CPC signal indicates to the terminals
connected to an eZ32-2 board that the remote party has hung up. Any terminal receiving a CPC
signal should hang up.
2.2. New features
2.2.1. Increasing provisioning level
Increase number of hunting groups: Up to 500 hunting groups per node (instead of 200).
Warning: The maximum number of hunting groups "in network" remains 200.
It is possible to manage up to 200 hunting groups where users can belong to several nodes.
Beyond, hunting groups users have to be managed on the same node.
Increase number of phone Class Of Service: Up to 256 Class Of Service (instead of 32).
Increase number of attendant groups: Up to 50 attendant groups per node (instead of 10).
Reminder: The maximum number of attendant groups per sub network remains 80.
Increase number of boss per secretary: Increase from 8 to 16 bosses per secretary. Number of
secretaries per boss is kept at 8.
2.2.2. Localization
Japanese support on Alcatel 4059 installed on Windows 7 OS.

Table of Contents

Other manuals for Alcatel-Lucent OmniPCX Enterprise

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Alcatel-Lucent OmniPCX Enterprise and is the answer not in the manual?

Alcatel-Lucent OmniPCX Enterprise Specifications

General IconGeneral
VoIP ProtocolsSIP, H.323
TypeIP PBX
VoIP CodecsG.711, G.729
IntegrationCRM
SecurityTLS, SRTP
ManagementWeb-based management
RedundancyYes, with redundant CPU and power supply