OmniPCX Enterprise
INSTALLATION PROCEDURE FOR VERSION
J1.410.34.c – RELEASE 10.0
Ed. 02 / 22 June 2011 53 TC1449
13. UPDATING THE BETA TEST SYSTEMS
All the Release 10 beta test sites should evolve to released version J1.410.34.c.
14. SYSTEM MANAGEMENT
Use the menu swinst/System management.
14.1 Declaring the automatic start-up of the telephone
Procedure
login
swinst
password
SoftInst
option 6
System management
option 2
Autostart management
option 1
Set autostart
14.2 Updating the date and time
Procedure
login
swinst
password
SoftInst
option 6
System management
option 2
Autostart management
option 1
Set autostart
15. CHECKING START-UP OF CPU/IO1/IO2/IO2N
CAUTION
− On a duplicated installation, if an IO2 or IO2N is declared in the database, it is essential that it
be present when starting up, otherwise the CPU will not restart. In fact, telephone signaling is now
processed by the IO2 or the IO2N when present (otherwise it is processed by the IO1 module of
the CPU as in previous versions). It is however possible to start without IO2 or IO2N using the
command
RUNTEL -DNOIO2 in mtcl.
− If this first start-up is carried out on a model, put in place at least one UA or Z coupler in place of
a UA or Z coupler of the site as this will allow the correct operation of the IO1 or the IO2/IO2N
to be checked.