EasyManuals Logo

Alcatel-Lucent OmniPCX Enterprise User Manual

Alcatel-Lucent OmniPCX Enterprise
108 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #103 background imageLoading...
Page #103 background image
OmniPCX Enterprise
INSTALLATION PROCEDURE FOR VERSION
J1.410.34.c – RELEASE 10.0
APPENDIX 2
REMARKS & RESTRICTIONS
Ed. 02 / 22 June 2011 31 TC1449
If the UTF-8 field is completed in user data with the same information as Latin name, the search
of name in the directory, using "Call by name", will give a double result ( Latin name + UTF-8
name).
16. BOARDS
MIX board.
This board is not supported in a Rack 3U in central area.
LIOB/LIOP/LIOX boards.
These boards are in phase out from Release 6.1. They are supported by Release 8.0 but can no
more be configured for addition or for new installation.
INT1/INT2 boards.
These boards are no more supported from Release 6.1.1. They must be replaced by
INTOF/INTOF2 boards. On a migration, Actis will remove the INT1 or INT2 boards and will
propose a preferential rate on INTOF2 boards.
INTOF2 board.
The mixing of various generation boards is allowed in a same rack but:
the couplers in relation to the link must be of the same type
the type of INTOF must be of the same type if the link is doubled or tripled
the INTOFS and INTOF2S are not compatible between them. If changing from INTOFS to
INTOF2S, you should also change the INTOFS which is faced to this board. No consistency
check is possible with the management because each board is part of a different node.
Nevertheless an anomaly will be sent by the INTOFS2 if the remote coupler is not the same.
DPT1-2 board.
NPRAE and DPT1-2 boards cannot be used together on the same PCX.
LANX16-1 / SLANX4 / LANX16-2 / LANX8-2.
These LAN switch boards are not manageable.
NDDI2 board.
In R6.2 NDDI2 board is available for Australia.
17. MISCELLANEOUS
Z sets ringing.
Maximum number of simultaneous ringing sets in a Rack 1U: 6.
Maximum number of simultaneous ringing sets Rack 3U: 20.
In the event where you should use a T1 access and an E1 access on the same system,
the two boards must be on different Media Gateway.
MIPT.
No music played during a music on hold.

Table of Contents

Other manuals for Alcatel-Lucent OmniPCX Enterprise

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Alcatel-Lucent OmniPCX Enterprise and is the answer not in the manual?

Alcatel-Lucent OmniPCX Enterprise Specifications

General IconGeneral
VoIP ProtocolsSIP, H.323
TypeIP PBX
VoIP CodecsG.711, G.729
IntegrationCRM
SecurityTLS, SRTP
ManagementWeb-based management
RedundancyYes, with redundant CPU and power supply

Related product manuals