Slow Drain Detection Adjust Value SdAd
This option allows the owner to increase or decrease the Slow
Drain Detection threshold by adding additional seconds to the
threshold value. When enabled it increases the time before a
Slow Drain Error will occur.
1. Control must be in Manual Mode. Refer to Entering the Man-
ual Mode.
2.
Press the #3 () or the #6 () keypad until Prog appears in
the display. Press the START (enter) keypad and dCYC will
appear in the display.
3. Press the #3 () or the #6 () keypad to scroll through the pro-
grammable options until SdAd appears in the display.
4.
When SdAd appears in the display, press the START (enter)
keypad. The current Slow Drain Detection Adjust value will
appear in the display.
on = Option Enabled
oFF = Option Disabled (default setting)
5. Press the #3 () or the #6 () keypad to change the current
value.
NOTE: The Slow Drain Detection Adjust Value can
be set from 0 to 255 seconds. The default Slow
Drain Detection Adjust value is 0.
6. Press the START (enter) keypad when the desired value ap-
pears in the display. The next option, rtC-, will appear in the
display.
NOTE: To program rtC- (Set Real-Time Clock), refer
to Set Real-Time Clock rtC-. To program other options,
refer to the appropriate section.