Error Codes
Following is a list of possible error codes for an electronic con-
trol. Errors beginning with EI refer to external device Infra-red
communication errors. All other errors refer to machine errors.
Display Description Cause/Corrective Action
EI01
Transmission Failure Communication failure. Re-aim external device and try again.
EI02
Time-out Error Communication failure. Re-aim external device and try again.
EI03
Invalid Command Code Communication successful, but the command was not valid for
this machine type, or the control could not perform the command
in its current mode of operation. Ensure data is for current ma-
chine type and control is in correct mode.
EI04
Expecting Upload Request Communication failure. Re-aim external device and try again.
EI05
Invalid or Out-of-Range Data The value in at least one of the programming options is invalid or
out of range. Recheck the programming option’s value and try
again.
EI09
CRC-16 Error Communication failure. Re-aim external device and try again.
EI0A
Framing Error Communication error. Re-aim external device and try again.
EI0C
Time-out Exceeded Communication error. Re-aim external device and try again.
EI0E
Encryption Error Communication error. Re-aim external device and try again. If
the problem persists, check that the security code is correct.
EI0F
Infra-red Disabled Communication failure or infra-red is disabled. Manually enable
infra-red on control or re-aim external device and try again.
E FL
Fill Error Programmed water level not reached within 10 minutes (or other
programmed length of time) in any fill agitate cycle. End cycle.
Power down machine to clear.
E SP
SPI Communications Error Front End control cannot communicate with output board. Power
down the machine, power up and try again.
E dL
Door Lock Error Door does not lock immediately upon closing (open and re-close
door) or doesn’t unlock 5 seconds after cycle completion. Power
down machine and retry.
E do
Door Open Error Control detects door open. Caused by pulling on door while
locked or about to lock. Correct inoperative door locking system.
End cycle. Power down machine to clear.
E Ub
Unbalance Error Unable to balance load. Redistribute load and run cycle.
door
Door Open Indicator Door is not closed in Start Mode. If door is closed, check for im-
proper wiring or faulty door switch.
E dr
Drain Alarm Error Machine not drained within 15 minutes (or other programmed
length of time) in any drain step. End cycle. Power down ma-
chine to clear.
Table 17 continues...
Error Codes
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
63 Part No. F8238101ENR11