Manual Diagnostics (Enable/Disable)
dAEn
This option allows the owner to enable or disable the manual di-
agnostics option. Refer to Testing Machine and Electronic Con-
trol Functions section for more information.
1. Control must be in Manual Mode. Refer to Entering the Man-
ual Mode.
2.
Press the #3 (∧) or the #6 (∨) keypad until Prog appears in
the display. Press the START (enter) keypad and dCYC will
appear in the display.
3. Press the #3 (∧) or the #6 (∨) keypad to scroll through the pro-
grammable options until dAEn appears in the display.
4.
When dAEn appears in the display, press the START (enter)
keypad. The current Manual Diagnostics status will appear in
the display.
on = Option Enabled (default setting)
oFF = Option Disabled
5. Press the #3 (∧) or the #6 (∨) keypad to change the current
status.
6. Press the START (enter) keypad when the desired status ap-
pears in the display. The next option, FLo, will appear in the
display.
NOTE: To program FLo (Low Water Level), refer to
Low Water Level FLo. To program other options, refer
to the appropriate section.
Low Water Level FLo
This option allows the owner to program the low water level dur-
ing fill and agitate of all cycles.
1. Control must be in Manual Mode. Refer to Entering the Man-
ual Mode.
2.
Press the #3 (∧) or the #6 (∨) keypad until Prog appears in
the display. Press the START (enter) keypad and dCYC will
appear in the display.
3. Press the #3 (∧) or the #6 (∨) keypad to scroll through the pro-
grammable options until FLo appears in the display.
4.
When FLo appears in the display, press the START (enter)
keypad. A number will appear in the display. This number
corresponds to the current low water level during agitate and
fill of all cycles.
5. Press the #3 (∧) or the #6 (∨) keypad to increase or decrease
the current water level to the desired water level.
NOTE: The Low Water Level value can be set from 1
to 10. The default Low Water Level value is 3.
6. Press the START (enter) keypad when the correct number ap-
pears in the display. The next option, FnEd, will appear in the
display.
NOTE: To program FnEd (Medium Water Level), refer
to Medium Water Level FnEd . To program other op-
tions, refer to the appropriate section.
Programming Control
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
49 Part No. F8238101ENR11